Professor, D.Sc., Ph.D. Marek Kozicki

2D textile dosimetry

Papers

  1.  Kozicki M., Sasiadek E.
    "Textile, UV detector with 2,3,5-triphenyltetrazolium chloride as an active compound", Radiat. Meas., 46, 510-526 (2011)

    Abstract
  2. Kozicki M., Sasiadek E.
    "UV dosimeter based on polyamide woven fabric and nitro blue tetrazolium chloride as an active compound", Radiat. Meas., 46, 1123-1137 (2011)

    Abstract
  3. Kozicki M., Sąsiadek E.
    "Polyamide woven fabrics with 2,3,5-triphenyltetrazoluim chloride or nitro blue tetrazolium chloride as 2D ionizing radiation dosimeters", Radiat. Meas., 47, 614-621 (2012)
    Abstract
  4. Sąsiadek E., Andrzejczak R., Kozicki M.
    "The importance of fabric structure in the construction of 2D textile radiation dosimeters", Radiat. Meas., 47, 622-627 (2012)

    Abstract
  5. Kozicki M., Sąsiadek E.
    Scanning of flat textile-based radiation dosimeters: Influence of parameters on the quality of results, Radiat. Measur., 58, 87-93 (2013)
    Abstract
  6. M. Kozicki, E. Sąsiadek-Andrzejczak, R. Wach, P. Maras
    Flexible Cotton Fabric-Based Ionizing Radiation Dosimeter for 2D Dose Distribution
    Measurements over a Wide Dose Range at High Dose Rates
    Int. J. Mol. Sci. 25, 2916, 2024
    Abstract

 Conference contributions

  1. M. Kozicki, P. Maras, E. Sąsiadek, K. Kwiatos, M. Jaszczak, M. Dudek
    Report on the 2D/3D dosimetry research in Lodz, Poland Group: past, present and the future
    Congress of Polish Society of Medical Physics, 50th anniversary of PSMP, Warsaw, Poland, September 3-5, 2015, Book of abstracts, p. 100 (Oral presentation) 
  2. E. Sąsiadek, P. Maras and M. Kozicki
    "Textile based dosimeter for 2D ionizing radiation measurements"
    Congress of Polish Society of Medical Physics, 50th anniversary of PSMP, Warsaw, Poland, September 3-5, 2015, Book of abstracts, p. 64 (Poster presentation)  
  3. E. Sasiadek, F. E. Rybicki and M. Kozicki
    "Textile dosimeters for ionizing radiation dose distribution measurements in radiotherapy",
    XI Conference of Faculty of Engineering and Marketing of Textile, 2008
  4. E. Sąsiadek and M. Kozicki
    "Textile dosimeters for ultraviolet and ionizing radiation measurements",
    4th European Young Investigator Conference, Collegium Polonicum, Słubice Poland, Book of abstracts, p.39 (O-17), June 18-21, 2009 
  5. E. Sąsiadek and M. Kozicki
    "Textile dosimeters for ultraviolet radiation measurements",
    XII Scientific Conference of Faculty of Material Technologies and Textile Design, 2009 
  6. E. Sąsiadek i M. Kozicki
    "Tekstylne dozymetry do pomiarów promieniowania ultrafioletowego" ang. "Textile dosimeters for ultraviolet radiation measurements"),
    52. Zjazd Polskiego Towarzystwa Chemicznego oraz Stowarzyszenia Inżynierów i Techników Przemysłu Chemicznego, Łódź, 12-16 września 2009, Książka abstraktów, str. 290 (komunikat ustny) 
  7. M. Kozicki, E. Sąsiadek, E. Rybicki
    "Composite textile-based systems antibacterialy active and radiation detectors",
    3rd International Congress on Competitive Innovation, Research and Technology-based Solutions, AITEX, October 28-29, 2009, Alcoy, Spain (poster presentation; materials on-line available at www.aitex.es for registered participants)

Patents

  1. M. Kozicki, E. Rybicki, E. Sąsiadek
    "Sposób wytwarzania dozymetru do pomiarów promieniowania UV, promieniowania jonizującego i rozkładów przestrzennych dawek promieniowania UV i promieniowania jonizującego" (eng. Method of preparation of dosimeter for UV light and ionizing radiation measurements and measurements of UV light and ionizing radiation dose distribution)
    Polish Patent No 208671 (2010.12.27); (submitted: 2007-09-03)