Professor, D.Sc., Ph.D. Marek Kozicki

2024

  1. M. Kozicki, Z. Stempień, B. Rokita, M. Dudek
    Sandwich-type channeled chemical hydrogels manufactured by 3D ink-jet printing
    under freezing conditions using a photochemical process for human cell cultures
    Chem. Eng. J. 481, 148401, 2024
    Abstract
  2. M. Jaszczak-Kuligowska, E. Sąsiadek-Andrzejczak and M. Kozicki
    Elastic TTC–PVA gel dosimeters for personal UV exposure measurements
    Measurement, 228, 114332, 2024
    Abstract
  3. M. Kozicki, E. Sąsiadek-Andrzejczak, R. Wach, P. Maras
    Flexible Cotton Fabric-Based Ionizing Radiation Dosimeter for 2D Dose Distribution
    Measurements over a Wide Dose Range at High Dose Rates
    Int. J. Mol. Sci. 25, 2916, 2024
    Abstract
  4. M. Kozicki, P. Maras, M. Jaszczak-Kuligowska
    3D Polymer Gel Dosimeters with iCBCT 3D Reading and polyGeVero-CT Software
    Package for Quality Assurance in Radiotherapy
    Materials 17, 1283, 2024
    Abstract
  5. M. Piotrowski, P. Maras and M. Kozicki
    On the Use of the Fricke-Pluronic F-127 Gel Dosimeter for Radiation Isocenter
    Testing of a Medical Linear Accelerator
    Materials 17 1521, 2024
    Abstract

2023

  1. Marek Kozicki, Marcin Bartosiak, Piotr Maras, Radosław Wach, Slawomir Kadlubowski
    First Combined, Double-Density LCV-Pluronic F-127 Radiochromic Dosimeter Mimicking
    Lungs and Muscles
    Adv. Mater. Technol. 2023, 2201023
    Abstract

  2. Marek Kozicki and Piotr Maras
    Dozymetria 3D w radioterapii. Rys historyczny, typy dozymetrów, charakterystyka i aplikacje
    (eng. 3D dosimetry in radiotherapy. Historical outline, types of dosimeters, characteristics and applications)Fizyk Inżynier Medyczny, 12(1), 27-43, 2023, ISSN 2300-1410 (in Polish)
    Link to the journal

  3. E. Sąsiadek-Andrzejczak, M. Kozicki
    Multi-Color Printed Textiles for Ultraviolet Radiation Measurements, Creative Designing, and Stimuli-Sensitive Garments. Materials 2023, 16, 5622.
    Abstract

  4. M. Kozicki, M. Jaszczak, P. Maras, S. Kadlubowski
    Measurement of the radiation dose and radiation isocenter of the TrueBeam accelerator using 3D polymer gel dosimeters from the VIPAR family with different chemical history
    Measurement 221, 113452, 2023
    Abstract

  5. E. Sąsiadek-Andrzejczak, M. Jaszczak, M. Kozicki
    Capsule Dosimeters for Ultraviolet Radiation Measurements on Coral Reefs and in Seawater
    Materials 16, 5734, 2023
    Abstract

  6. M. Kozicki, P. Maras
    On the measurement of radiation isocenter for medical accelerators using 3D polymer gel dosimetry. Introduction, application, and good practices
    Measurement, 221, 113585, 2023
    Abstract

  7. M. Dudek, E. Sąsiadek-Andrzejczak, M. Jaszczak-Kuligowska, B. Rokita, and M. Kozicki
    The Surface Modification of Papers Using Laser Processing towards Applications
    Materials, 16, 6691, 2023
    Abstract

2022 

  1. Maras P., Kozicki M.
    Fast Isocenter Determination Using 3D Polymer Gel Dosimetry with Kilovoltage Cone-Beam CT Reading
    and the PolyGeVero-CT Software Package for Linac Quality Assurance in Radiotherapy
    Materials 15 (2022) 15 6807
    Abstract
  2. Michał Piotrowski, Piotr Maras, Sławomir Kadłubowski and Marek Kozicki
    Study of the Optimal Composition and Storage Conditions of the Fricke−XO−Pluronic F−127 Radiochromic Dosimeter
    Materials,15, 984 (2022)
    Abstrac
  3. Elzbieta Sasiadek-Andrzejczak, Agata Madrakowska and Marek Kozicki
    Study of NBT–Pluronic F–127 Gels as 1D UV Radiation Dosimeters for Measurement of Artificial Light Sources
    Materials, 15, 2370 (2022)
    Abstract
  4. Malwina Jaszczak, Elżbieta Sąsiadek‐Andrzejczak and Marek Kozicki
    Discolouring 3D Gel Dosimeter for UV Dose Distribution Measurements
    Materials, 15, 2546 (2022)
    Abstract
  5. Marek Kozicki, Malwina Jaszczak and Piotr Maras
    Features of PABIGnx 3D Polymer Gel as an Ionising Radiation Dosimeter
    Materials, 15, 2550 (2022)
    Abstract
  6. Marek Kozicki, Aleksandra Pawlaczyk, Aleksandra Adamska, Małgorzata Szynkowska-Jóźwik, Elżbieta Sąsiadek-Andrzejczak
    Golden and Silver–Golden Chitosan Hydrogels and Fabrics Modified with Golden Chitosan Hydrogels
    Int. J. Mol. Sci. 23, 5406 (2022)
    Abstract
  7. Michał Piotrowski, Piotr Maras, Radosław Wach, Slawomir Kadlubowski and Marek Kozicki
    Impact of Salt on Thermal Stability and Dose Response of the Fricke-XO-Pluronic F-127 3D Radiotherapy Dosimeter
    Materials 15, 5223 (2022)
    Abstract
  8. Dudek, M., Wawryniuk, Z., Nesteruk, M., Rosowski, A., Cichomski, M., Kozicki, M., Święcik, R.
    Changes in the Laser-Processed Ti6Al4V Titanium Alloy Surface Observed by Using Raman Spectroscopy. 
    Materials 2022, 15, 7153.
    Abstract
  9. Kozicki, M., Maras P.
    Features of 2Day.QA® as a 2D radiation dosimeter
    Phys. Medica, 2022, 104, 23-31
    Abstract

2021

  1. Kozicki M., Bartosiak M., Dudek M., Kadlubowski S.
    LCV-Pluronic F-127 dosimeter for UV light dose distribution measurements
    J. Photochem. Photobiol. A 405 112930 (2021) 
    Abstract
  2. Jaszczak M., Sasiadek E., Kadlubowski S., Dudek M., Kozicki M.
    Preliminary study on a new 3D radiochromic KI-Pluronic F-127 gel dosimeter for radiotherapy
    Radiat. Phys. Chem. 185 109507 (2021) 
    Abstract
  3. Kozicki M., Jaszczak M., Maras P., Naglik R., Dudek M., Kadlubowski S., Wach R.
    Preliminary study on a 3D lung mimicking dosimeter based on Pluronic F-127 matrix
    Radiat. Phys.Chem. 185 109479 (2021) 
    Abstract
  4. Sąsiadek E., Jaszczak M., Skwarek J., Kozicki M.
    NBT‐Pluronic F‐127 Hydrogels Printed on Flat Textiles as UV Radiation Sensors
    Materials 14 3435 (2021)
    Abstract
  5. Kozicki M., Jaszczak M., Dudek M., Maras P.
    Laser Light Trapping Phenomenon in a 3D Radiotherapy Polymer Gel Dosimeter
    Materials 2021, 14, 3961
    Abstract
  6. Sąsiadek E., Olejnik K., Kozicki M.,
    Paper Doped with Polyacrylonitrile Fibres Modified with 10,12–Pentacosadiynoic Acid
    Materials 2021, 14, 4006
    Abstract
  7. Dudek M., Piotrowski M., Maras P., Jaszczak M., and Kozicki M.
    Anisotropic diffusion of Fe ions in Fricke-XO-Pluronic F-127 and Fricke-XO-gelatine 3D radiotherapy dosimeters
    Phys. Med. Biol. 66 (2021) 155005
    Abstract
  8. Maras P., Jaszczak M., and Kozicki M.
    Basic features of VIC-T dosimeter with spiral CT readout, CT scanning conditions and data processing with a new polyGeVero-CT software package
    Radiat. Phys. Chem. 189 (2021) 109730
    Abstract

2020

  1. Kozicki M., Berg A., Maras P., Jaszczak M., Dudek M.
    Clinical radiotherapy application of N-vinylpyrrolidone-containing 3D
    polymer gel dosimeters with remote external MR-reading
    Physica Medica 69 (2020) 134–146 
    Abstract
  2. Kozicki M., Sąsiadek E., Kadlubowski S., Dudek M., Karbownik I.
    Radiation sensitive polyacrylonitrile microfibres doped with PDA nanoparticles
    Radiat. Phys. Chem. 169 (2020) 107751
    Abstract
  3. Sąsiadek E. and Kozicki M.
    A method of 1D UVC radiation dose measurement using a novel tablet dosimeter
    AUTEX Research Journal 20 (2020) 140-147 (DOI 10.2478/aut-2020-0005)
    Abstract
  4. Skorupa A., Woznica A., Ciszek M., Staniszewski M., Kijonka M., Kozicki M., Wozniak B., Orlef A., Polanski A., Boguszewicz Ł., Sokoł M.
    Application of high field magnetic resonance microimaging in polymer gel dosimetry
    Med. Phys. 47 3600-3613 (2020)
    Abstract
  5. Jaszczak M., Maras P. and Kozicki M.
    Characterization of a new N-vinylpyrrolidone-containing polymer gel dosimeter with Pluronic F-127 gel matrix
    Radiat. Phys. Chem. 177 109125 (2020) (https://doi.org/10.1016/j.radphyschem.2020.109125
    Abstract
  6. Kozicki M., Bartosiak M., Dudek M., Kadlubowski S.
    LCV-Pluronic F-127 dosimeter for UV light dose distribution measurements
    J. Photochem. Photobiol. A,  (2020) 112930
    Abstract

2019

  1. Jaszczak M., Kolesińska B., Wach R., Maras P., Dudek M. and Kozicki M.
    Examination of THPC as an oxygen scavenger impacting VIC dosimeter thermal stability and comparison of NVP-containing polymer gel dosimeters
    Phys. Med. Biol. 64 035019 (2019) 
    Abstract 
  2. Z. Stempien, M. Khalid, M. Kozicki, M. Kozanecki, H. Varela, P. Filipczak, R. Pawlak, E .Korzeniewska, E. Sąsiadek
    In-situ deposition of reduced graphene oxide layers on textile surfaces by the reactive inkjet printing technique and their use in supercapacitor applications
    Synthetic Metals 256 (2019) 116144
    Abstract
  3. Kouvati K, Jaszczak M, Papagiannis P, Kadlubowski S, Wach R, Maras P, Dudek M and Kozicki M
    Leuco crystal violet-Pluronic F-127 3D radiochromic gel dosimeter
    Phys. Med. Biol. 64 (2019) 175017 (14pp)
    Abstract

  4. M Kozicki, M Jaszczak, K Kwiatos, P Maras, S Kadlubowski, R Wach and
    M Dudek
    Three-dimensional radiochromic and polymer gel dosimeters with Pluronic F-127 matrix – a review of current research
    Journal of Physics: Conf. Series 1305 (2019) 012035
    Abstract

  5. M Kozicki, M Jaszczak, P Maras and M Dudek
    A chemical evolution of NVP-containing VIPAR-family 3D polymer gel dosimeters – a brief overview
    Journal of Physics: Conf. Series 1305 (2019) 012067
    Abstract

2018

  1. Kozicki M., Kwiatos K., Dudek M., Stempien Z. 
    Radiochromic gels for UV radiation measurements in 3D
    Journal of Photochemistry and Photobiology A: Chemistry 351 197–207 (2018)
    Abstract

  2. Kozicki M., Sasiadek E., Kadłubowski S., Dudek M., Maras P., Nosal A., Gazicki-Lipman M.
    Flat foils as UV and ionising radiation dosimeters
    Journal of Photochemistry and Photobiology A: Chemistry 351 179–196 (2018) 
    Abstract
  3. Kozicki M., Sąsiadek E., Kadlubowski S., Dudek M., Karbownik I.
    Radiation sensitive polyacrylonitrile microfibres doped with PDA nanoparticles
    Radiat. Phys. Chem. (2018), https://doi.org/10.1016/j.radphyschem.2018.01.021
    Abstract

  4.  Kwiatos K.Maras P.Kadlubowski S.Stempień Z.Dudek M. and Kozicki M.
    Tetrazolium salts-Pluronic F-127 gels for 3D radiotherapy dosimetry 
    Phys. Med. Biol. 63  095012 (10pp) (2018)
    Abstract

  5. Jaszczak M., Wach R., Maras P., Dudek M. and Kozicki M. 
    Substituting gelatine with Pluronic F-127 matrix in 3D polymer gel dosimeters can improve nuclear magnetic resonance, thermal and optical properties 
    Phys. Med. Biol. 63 (2018) 175010 (15pp)
    Abstract

  6. Stempien Z., Kozicki M., Kozanecki M., Pawlak R., Korzeniewska E., Owczarek G., Poscik A.
    Using the reactive inkjet printing technique to fabricate the gas sensors on textile substrates
    International Journal of Engineering Sciences vol. 11, no. 2 (2018), 43-48, ISSN: 0976-6693


2017

  1. Kozicki M., Jaszczak M., Maras P., Dudek M., Cłapa M.
    On the development of a VIPARnd radiotherapy 3D polymer gel dosimeter
    Phys. Med. Biol. 62 986–1008 (2017)
    Abstract 

2016

  1.  Kozicki M., Kołodziejczyk M., Szynkowska M., Pawlaczyk A., Lesniewska E., Matusiak A., Adamus A., Karolczak A.
    Hydrogels made from chitosan and silver nitrate
    Carbohydr. Polym., 140, 74–87 (2016) 
    Abstract
  2. Z. Stempień, M. Kozicki, R. Pawlak, E. Korzeniewska, G. Owczarek, A. Pościk, D. Sajna
    Ammonia gas sensors ink-jet printed on textile substrates
    Proceedings of IEEE Sensors, 2016
    Abstract 

2015

  1. Kozicki M. and Maras P.
    The polyGeVero® software for fast and easy computation of 3D radiotherapy dosimetry data 
    J. Phys.: Conf. Ser., 573, 012070 (2015) (a conference paper: IC3DDose, Ystad, Sweden, September 2014)
    Abstract

  2. Kozicki M., Sasiadek E., Karbownik I., Maniukiewicz W.
    Doped polyacrylonitrile fibres as UV radiation sensors 
    Sensor. Actuat. B-Chem., 213, 234–243 (2015)
    Abstract

  3.  Kozicki M., Maras P., Karwowski A.C.
     Introduction to polyGeVero® software for 3D radiotherapy dosimetry
     GeVero Co. publication, November 4, 2015, pages 1-17
     Full text 

2014

  1. Kozicki M., Maras P., Karwowski A.C. 
    Software for 3D radiotherapy dosimetry. Validation. Phys. Med. Biol., 59, 4111-4136 (2014)
    Abstract
     

2013

  1. Kozicki M., Sąsiadek E., Kołodziejczyk M., Komasa J., Adamus A., Maniukiewicz W., Pawlaczyk A., Szynkowska M., Rogowski J., Rybicki E.
    "Facile and durable antimicrobial finishing of cotton textiles using a silver salt and UV light, Carbohydr. Polym., 91, 115-127 (2013)",

    Abstract
     
  2. Kozicki M., Sąsiadek E.
    Scanning of flat textile-based radiation dosimeters: Influence of parameters on the quality of results, Radiat. Measur., 58, 87-93 (2013)
    Abstract
     

2012

  1. Kozicki M., Sąsiadek E.
    "UV-assisted screen-printing of flat textiles, Color. Technol., 128, 251-260 (2012) (Feature article)",

    Abstract

  2. Kozicki M., Sąsiadek E.
    "Polyamide woven fabrics with 2,3,5-triphenyltetrazoluim chloride or nitro blue tetrazolium chloride as 2D ionizing radiation dosimeters, Radiat. Meas., 47, 614-621 (2012)",

    Abstract

  3. Sąsiadek E., Andrzejczak R., Kozicki M.
    "The importance of fabric structure in the construction of 2D textile radiation dosimeters, Radiat. Meas., 47, 622-627 (2012)",

    Abstract

  4. Sobotka P., Kozicki M., Maras P., Boniecki Ł., Kacperski K. and Domański A.W.
    "Optical Scanner for 3D Radiotherapy Polymer Gel Dosimetry, Acta Phys. Pol. A, 122, 969-974 (2012)",

    Abstract

2011

  1. Kozicki M., Sasiadek E.
    "Textile, UV detector with 2,3,5-triphenyltetrazolium chloride as an active compound, Radiat. Meas., 46, 510-526 (2011)",

    Abstract

  2. Kozicki M., Sasiadek E.
    "UV dosimeter based on polyamide woven fabric and nitro blue tetrazolium chloride as an active compound, Radiat. Meas., 46, 1123-1137 (2011)",

    Abstract

  3. Kołodziejczyk M., Kozicki M., Rosiak J.M., Bielecki S.
    "Attempt to the construction and application of hybrid artificial organs, Military Pharmacy and Medicine, 4, 13-19 (2011)",

    Abstract

  4. Kozicki M.
    "How do monomeric components of a polymer gel dosimeter respond to ionising radiation: A steady-state radiolysis towards preparation of a 3D polymer gel dosimeter, Radiat. Phys. Chem., 80, 1419-1436 (2011)",

    Abstract

2009

  1. Petrokokkinos L., Kozicki M., Pantelis E., Antypas C., Fijuth J., Karaiskos P., Sakelliou L., Seimenis I.
    "Characterization of a new polymer gel for radiosurgery dosimetry using Magnetic Resonance Imaging, JINST, 1-5 (2009)",

    Abstract

  2. Kozicki M., Maras P., Rybka K., Biegański T.
    "VIPARnd - GeVero tool in planning of TPS scheduled brain tumour radiotherapy, JPCS, 164, 12061 (2009)",

    Abstract

  3. Kozicki M., Maras P., Jankowski J. and Karwowski A.C.
    "Polymer gel - TPS radiotherapy dosimetry GeVero software for ionizing radiation absorbed dose 3D distribution calculations, JPCS, 164, 12062 (2009)",

    Abstract

2008

  1. Pantelis E., Antypas C., Petrokokkinos L., Karaiskos P., Papagiannis P., Kozicki M., Georgiou E., Sakelliou L. and Seimenis I.
    "Dosimetric characterization of CyberKnife radiosurgical photon beams using polymer gels, Med. Phys, 35, 2312-2320 (2008)",

    Abstract

2007

  1. Kozicki M., Maras P., Rybka K., Bieganski T., Kadłubowski S., Petrokokkinos L.
    "On the development of the VIPAR polymer gel dosimeter for three-dimensional dose measurements, Macromol. Symp., 254, 345-352 (2007)",

    Abstract

2005

  1. Karaiskos P., Petrokokkinos L., Tatsis E., Angelopoulos A., Baras P., Kozicki M., Papagiannis P., Rosiak J.M., Sakelliou L., Sandilos P., Vlachos L.
    "Dose verification of single shot gamma knife applications using VIPAR polymer gel and MRI, Phys. Med. Biol., 50, 1235-1250 (2005)",

    Abstract

  2. Filipczak K., Janik I.,Kozicki M., Ulański P., Rosiak J.M., Pajewski L.A., Olkowski R., Woźniak P., Chróścicka A. i Lewandowska-Szumieł M.
    "Porous polymeric scaffolds for bone regeneration; e-Polymers, 011 (2005)",

    Abstract

  3. Pappas E., Petrokokkinos L., Angelopoulos A., Maris T.G., Kozicki M., Dalezios I., Kouloulias V.
    "Relative Output Factor measurements of a 5 mm diameter radiosurgical photon beam using polymer gel dosimetry, Med. Phys., 32, 1513-20 (2005)",

    Abstract

  4. Papagiannis P., Karaiskos P., Kozicki M., Rosiak J.M., Sakelliou L., Sandilos P., Seimenis I. Torens M.
    "Three dimensional dose verification in clinical applications of gamma knife stereotactic radiosurgery using polymer gel and MRI, Phys. Med. Biol., 50 1979-1990 (2005)",

    Abstract

  5. Pantelis E., Lymperopoulou G., Papagiannis P., Sakelliou L., Stiliaris S., Sandilos P., Seimenis I., Kozicki M. and Rosiak J.M.
    "Polymer gel dosimetry close to an 125I interstitial brachytherapy seed, Phys. Med. Biol. 50, 4371-4384 (2005)",

    Abstract

  6. Woźniak P., Kozicki M., Rosiak J.M., Przybylski J., Lewandowska-Szumieł M.
    "Alginate hydrogel candidate support for cell transplantation, e-Polymers, 029, (2005)",

    Abstract

  7. Rosiak J.M., Ulanski P., Kujawa P., Janik I., Stasica P., Kadlubowski S., Kozicki M.
    "Radiation-induced transformations of polymers in aqueous solutions, Eurasian Chem. Tech. Journal, 7, 225-250, (2005)",

    Abstract

2004

  1. Sandilos P., Angelopoulos A., Baras P., Dardoufas K., Karaiskos P., Kipouros P., Kozicki M., Rosiak J.M., Sakelliou L., Seimenis I., Vlahos L.
    "Dose verification in clinical IMRT prostate incidents, Int. J. Radiat. Oncol. Biol. Phys., 59, 1540-1547 (2004)",

    Abstract

  2. Pantelis E., Karlis A.K., Kozicki M., Papagiannis P., Sakelliou L., Rosiak J.M.
    "Polymer gel water equivalence and relative energy response with emphasis on low photon energy dosimetry in brachytherapy, Phys. Med. Biol., 49, 3495-3514 (2004) (nominated by the Publishing team of Physics in Medicine and Biology for inclusion in the Highlights of 2004)",

    Abstract

2003

  1. Kozicki M., Filipczak K., Rosiak J.M.
    "Reactions of hydroxyl radicals, H atoms and hydrated electrons with N,N'-methylenebisacrylamide in aqueous solution. A pulse radiolysis study, Radiat. Phys. Chem., 68, 827-835 (2003)",

    Abstract

  2. Rosiak J.M., Janik I., Kadlubowski S., Kozicki M., Kujawa P., Stasica P., Ulanski P.
    "Nano-, micro- and macroscopic hydrogels synthesized by radiation technique, Nucl Instr and Meth B, 208, 325-330 (2003)",

    Abstract

  3. Kipouros P., Papagiannis P., Sakelliou L., Karaiskos P., Sandilos P., Baras P., Seimenis I., Kozicki M., Anagnostopoulos G., Baltas D.
    "3D dose verification in 192Ir HDR prostate monotherapy using polymer gels and MRI, Med. Phys., 30, 2031-2039 (2003)",

    Abstract

2002

  1. Kozicki M., Kujawa P., Rosiak J.M.
    "Pulse radiolysis study of diacrylate macromonomer in aqueous solution, Radiat. Phys. Chem., 65, 133-139 (2002)",

    Abstract

  2. Ulanski P., Janik I., Kadlubowski S., Kozicki M., Kujawa P., Pietrzak M., Stasica P. and Rosiak J.M.
    "Polymeric Biomaterials Synthesized by Radiation technique - Current Studies at IARC Poland, Polym. Adv. Technol., 13, 951-95 (2002)",

    Abstract

  3. Rosiak J.M., Janik I., Kadlubowski S., Kozicki M., Kujawa P., Stasica P., Ulanski P.
    "Radiation formation of hydrogels for biomedical application, in: Radiation synthesis and modification of polymers for biomedical applications, Final results of a co-ordinated research project 19962000",

    ISBN 920119702, 5-48, IAEA, VIENNA, 2002

1999

  1. Kozicki M., Kujawa P., Pajewski L., Kolodziejczyk M., Narebski J., Rosiak J.M.
    "Encapsulation of living cells toward artificial, hybrid organs, Eng. Biomaterials, 7-8, 11-15 (1999)",

    Abstract